Two methods of Brazed Radiator cleaning
Brazed Radiator is very widely used in modern our domestic production industry a cooler, it bring great convenience to our production and work. If you want to make the oil cooler for longer service life, reduce the generation of fault, so we shall timely cleaning, here small make up mainly introduce the two methods for cleaning oil cooler.
Water side cleaning: clean the front cover of clean water with the hose, the inner wall of the back cover and the inner surface of the heat exchange tube, wash with the cleaning agent, and blow dry with compressed air after washing
Oil side cleaning:
(1) choose a suitable cleaning agent, the content is very important, we usually according to the tube produced by some impurity elements to determine choice is organic acid cleaner or inorganic acid detergent, choose a suitable cleaner can help us easily to remove impurities.
(2) chemical b dilute solution to wash, make the cleaning fluid circulating in the cooler, the solution of pressure is not greater than 0.6 Mpa, the flow of solution and the best Brazed Radiator oil flow in the opposite direction, cleaning time subject to dirt, then will be clean water into the cooler, until the water clean.
(3) the solution into the Brazed Radiator with immersion method, 15-20 minutes to check the solution color, if be turbid, the new solution, soaking, again until clean, then rinse with clear water.
Cleaning process requirement is very strict and important, after using acidic detergent cleaning shall be conducted by alkaline clean water is needed to clean, such neutralization after rule out completely, can help us to clean the oil cooler is more clean and completely.
In the operation of the unit, brazing Brazed Radiator radiator manufacturer may occur at the bottom of the end cover fault of leakage or leakage, and especially in the process of the unit startup or shutdown, fault occurred more frequently, now let's tell you why.
1) when the unit is started or stopped, the oil side of the Brazed Radiator and the water side often fluctuate, causing the o-ring to move and cause it to leak.
2) when the Brazed Radiator unit is installed, the clearance of the o-type sealing ring will be abnormal if the inner core of the Brazed Radiator is installed. In operation, if there is a slight pressure (oil side, water side) fluctuation, it will cause leakage.
3) every time Brazed Radiator in the process of inspection, replacing type O sealing ring, because the bottom end cover is narrow, maintenance, installation inconvenience, tend to appear o-rings are broken copper bed pressure, near the leak. After each overhaul, the probability of leakage on the water side exceeds the oil side, which proves that the current design is not easy to overhaul and ensure the quality of maintenance.
Brazed Radiator isolation between oil, water and oil and water leakage of all rely on two type O sealing ring, if two o-rings break or shift, cause gap change, is bound to cause leakage. Because the sealing cover of the o-ring is on the left and right side, instead of the traditional upper and lower sides, as soon as the leakage occurs, the tightening of the flange bolt can not reduce the leakage. After analysis, the above is the cause of the clearance change and breakage of O - type sealing ring.